Hioki Memory HiLoggers are high-speed data loggers for recording multiple chanels of voltage, temperature, pulse or rotation signals, providing complete isolation between channels and strong noise resistance. The Hioki LR8432 is a handheld 10-channel data logger especially designed for heat flow measurement. The Heat Flow Logger is ideal for evaluating insulation performance and analyzing the causes of temperature change.
- Use a heat flow sensor to measure the movement and volume of heat energy
- Measure of temperature and voltage
- Record measurement data on a USB flash drive for easy transfer to a computer
- Record to reliable Compact Flash cards during long-term measurement applications for increased peace of mind
- Ten isolated analog input channels
- 10 ms sampling and recording across all channels
- Record raw waveforms and post-calculation waveforms at the same time. (Heat transmission coefficient processing)
- Two graduations can be displayed with a double gauge
The LR8432-20 is a heat flow logger that visualizes quantities of heat.
By using a heat flow sensor to visualize movements of thermal energy (heat flows) and quantities of thermal energy, you can obtain data that serves as a leading indicator of changes in temperature.
Visualizing heat flows (inflows and outflows) and quantities of heat with a heat flow logger is useful when you need to implement more precise air-conditioning control or formulate thermal measures as part of the product development process.
- Isolation of heat generated and dissipated in automotive parts
- Evaluate the thermal performance of building materials
- Measure the energy efficiency of consumer electronics
- Study the impact of body heat
- Diagnose the deterioration of insulation material in plant piping
- Index temperature fluctuation in agriculture and civil engineering
- Quality control of food storage
- Development of materials, sportswear and winter wear etc.
Heat flow and temperature gauges can be displayed simultaneously for data measured with the Heat Flow Logger LR8432-20.
Display the gauges for data you want to compare at the same time in order to see changes in temperature and heat flow at a single glance.
Basic specifications
1. Specialized functions for heat flow measurement: - Easy scaling settings: directly enter the sensitivity of the heat flow sensor - Calculations: waveform processing function for the analysis of temperature and heat flow (Simple average, moving average, integration, heat transmission coefficient), Integration with numerical calculations
2. Analog inputs: [No. of channels] 10 isolated analog channels using scanning input method (M3 mm dia. screw terminal block) / [Voltage measurement range] ±10 mV to ±60 V, 1-5V, Max. resolution 500 nV / [Temperature : thermocouples] −200 ˚C to 1800 ˚C (depending on sensor), thermocouples (K, J, E, T, N, R, S, B), Max. resolution 0.1 ˚C / [Humidity] not available / [Max. allowable input] 60 V DC / [Max. rated voltage between input channels] [Max. rated voltage to earth] / 30 AC Vrms, 60 V DC (max. voltage between input channel terminals, and from terminals to chassis ground without damage)
3. Pulse inputs: [No. of channels] 4 pulse input channels (requires CONNECTION CABLE 9641, all pulse inputs share common ground with the main unit) / [Totalized pulses] 0 to 1000M (count) (No-voltage ‘a’ contact, open collector or voltage input), Max. resolution 1 pulse / [Rotation count] 0 to 5000/n (r/s), Resolution 1/n (r/s) * n = pulses per rotation (1 to 1,000) / [Max. allowable input] 0 to 10 V DC / [Max. rated voltage between input channels] [Max. rated voltage to earth] Non-isolated
4. Recording intervals: 10 ms to 1 hour, 19 selections (All input channels are scanned at high speed during every recording interval)
5. Selectable filters: 50 Hz, 60 Hz, or OFF (digital filtering of high frequencies on analog channels)
6. Memory capacity: Internal storage: 3.5 M-words, External storage: CF card or USB memory stick (only the HIOKI CF cards are guaranteed for correct operation)
7. External interface: USB 2.0 mini-B receptacle ×1; Functions: Control from a PC, Transfers files from the installed CF card to a PC (cannot transfer files from the connected USB memory stick to a PC via USB communication), Data copy between CF card and USB memory stick
8. Display: 4.3-inch WQVGA-TFT color LCD (480 × 272 dots)
9. Functions: Save data to the CF Card or USB memory stick in real time, Numerical Calculations, etc.
10. Power supply: AC Adapter Z1005: 100 to 240 VAC (50/60 Hz), 30 VA Max. (including AC adapter), 10 VA Max. (main unit only) / Battery Pack 9780: Continuous use 2.5 hours (@25°C/77°F), 3 VA Max. / External power source: 10 to 16 V, 10 VA Max. (please contact HIOKI distributor for cable; less than 3 m/9.84 ft cable length)
11. Dimensions and mass: 176 mm (6.93 in) W × 101 mm (3.98 in) H × 41 mm (1.61 in) D, 550 g (19.4 oz) (Battery Pack 9780 not installed)
12. Included accessories: Measurement Guide ×1, CD-R (Instruction manual PDF, Logger Utility Instruction Manual PDF, Data acquisition application program Logger Utility) ×1, USB cable ×1, AC Adapter Z1005 ×1
There are no reviews for this product.